Program Data Dump
Status Description
1111 0000 System Exclusive (SysEx)
0000 0001 DSI ID
0010 0000 Evolver ID
0000 0001 File Version
0000 0010 Program Data
0000 00vv Bank Number, 0 - 3
0vvv vvvv Program Number, 0 - 127
0vvv vvvv 220 bytes in “packed MS bit” format (see page 54). Includes 128 bytes of
Program parameters and 64 bytes of Sequence data.
1111 0111 End of Exclusive (EOX)
Program Name Data Dump
Status Description
1111 0000 System Exclusive (SysEx)
0000 0001 DSI ID
0010 0000 Evolver ID
0000 0001 File Version
0001 0001 Program Name Data
0000 00vv Bank Number, 0 - 3
0vvv vvvv Program Number, 0 - 127
0vvv vvvv 16 name data bytes. Note that the Poly Evolver stores the basic 7 bit data.
The assumption is that the data is ACSCII
1111 0111 End of Exclusive (EOX)
Combo Data Dump
Status Description
1111 0000 System Exclusive (SysEx)
0000 0001 DSI ID
0010 0000 Evolver ID
0000 0001 File Version
0010 0010 Combo Data
0000 00vv Bank Number, 0 - 2
0vvv vvvv Combo Number, 0 - 127
0vvv vvvv 92 bytes in “packed MS bit” format (see page 54) = 80 bytes of Combo data
1111 0111 End of Exclusive (EOX)